TOPIC 3
Test Methods to Predict
Moisture Sensitivity of
Hot-Mix Asphalt Pavements
77
TOPIC 3
Test Methods to Predict Moisture Sensitivity of Hot-Mix Asphalt
Pavements
MANSOUR SOLAIMANIAN
Pennsylvania State University
J
OHN HARVEY
University of California, Davis
M
AGHSOUD TAHMORESSI
PaveTex Engineering and Testing
V
IVEK TANDON
University of Texas at El Paso
The work conducted through the years toward development of moisture damage tests is
summarized in this paper. Moisture damage has been a major concern to asphalt technologists
for many years. Attempts to develop laboratory tests to distinguish between good- and poor-
performing mixes in regard to stripping date back to the 1920s.
The tests for identifying the moisture damage potential of an asphalt–aggregate mixture
can be classified into two major categories: those on loose mixtures and those on compacted
mixtures. The static immersion and the boil test, both conducted on loose mixtures, were among
the first tests introduced to the paving industry. This was followed by introduction of the
immersion–compression test in the late 1940s. This test was conducted on compacted specimens
and was the first test to become an ASTM standard in the mid-1950s. Research in the 1960s
brought considerable awareness to asphalt pavement technologists of the significant effects of
climate and traffic on moisture damage. The significance of these factors was emphasized
through the work of researchers such as Johnson (1969), Schmidt and Graf (1972), Jiminez
(1974), and Lottman (1978).
The work by Jiminez resulted in a laboratory test simulating the effect of repeated water
pressure on the behavior of saturated hot-mix asphalt. Extensive work by Lottman resulted in the
laboratory test that currently has the widest acceptance in the paving industry. This test was
further modified through the work of Tunnicliff and Root (1982). Wheel tracking of asphalt
mixes submerged under water gained popularity for determination of moisture damage in the
1990s. The Hamburg wheel-tracking device and the asphalt pavement analyzer are among the
tests of this type. It was also during this period that the environmental conditioning system was
introduced to the industry at the completion of the Strategic Highway Research Program (SHRP)
in 1993.
The Superpave system, the product of SHRP, adopted the standard test method AASHTO
T283 as the required test for determination of the risk of moisture damage. This test procedure is
similar to the Lottman test procedure with some modification. With the Superpave system being
adopted by most state highway agencies, AASHTO T283 became the most widely used test
78 Moisture Sensitivity of Asphalt Pavements: A National Seminar
procedure within the industry. Some agencies have reported problems with this test in terms of
correlation between the laboratory results and field observations.
Today, it remains a challenge to asphalt pavement technologists to develop a highly
reliable and practical test procedure for determination of moisture damage. An important
consideration in development and acceptance of a test procedure for moisture damage should be
calibration of the test to the conditions for which it will be applied. Some tests have been
calibrated and implemented on a local basis (a region within a state). No test has been
successfully calibrated and implemented across a wide spectrum of conditions. Reasons for this
have been lack of correlation with field performance, a lack of good field performance databases,
and problems with the tests such as variability and difficulty of operation.
INTRODUCTION
Historical Development
The performance of hot-mix asphalt (HMA) in the presence of water is a complex issue and has
been the subject of numerous research studies during the past six decades. During this period,
asphalt technologists and state highway agencies have been in pursuit of a reliable laboratory test
protocol to predict the asphalt pavement behavior in the field with regard to moisture sensitivity.
The facts that the adhesion between asphalt and aggregate is reduced in the presence of water
(stripping) and that the cohesion within the asphalt binder itself deteriorates have been known to
practitioners for a long time and date back to at least the 1920s. Early work on this problem was
performed by Nicholson (1932), Riedel and Weber (1934), McLeod (1937), Hubbard (1938),
Powers (1938), Winterkorn et al. (1937), Saville and Axon (1937), Winterkorn (1937; 1938;
1939), Krchma and Nevitt (1942), Krchma and Loomis (1943), and Hveem (1943), among
others. An extensive bibliography covering work performed prior to 1959 is given by Rice
(1958).
Examination of the 1937 Proceedings of the Association of Asphalt Paving
Technologists (AAPT) shows two papers on asphalt–aggregate adhesion and problems with
moisture sensitivity and references to previous work. For example, a paper by Saville and Axon
discusses the search for a usable laboratory test and presents results from boiling tests and
soaking tests and compares them with the field stripping performance of mixes with different
types of aggregate. That paper also contains photographs of stripped mixes that would all be
recognized from pavements today (as a note, this indicates that stripping problems did not begin
because of changes in asphalt composition in the early 1980s). In an update on asphalt test
development in the 1943 AAPT Proceedings, Hveem commented on the problem and stated:
A complete solution to this entire problem may readily appear from another
source. That is to say, that there are now many methods of treatment being
advocated or in process of development which should improve the capacity of any
asphalt to stick to virtually all aggregates under the most adverse conditions.
When an agent is commercially available that can be added to the asphalt at the
refinery, this entire problem may largely disappear, although it is likely that
accurate test methods will always be needed in order to compare the effectiveness
of competing forms of treatment.
Solaimanian, Harvey, Tahmoressi, and Tandon 79
The immersion–compression test was introduced in 1950s as the first moisture damage
test on compacted specimens under ASTM standard. In that decade, some work was also
conducted on the surface energy of asphalt and aggregate and its relationship to bonding
properties (Thelen 1958). Andersland and Goetz (1956) also introduced the sonic test for
evaluation of stripping resistance in compacted bituminous mixtures.
More recent attempts toward development of tests to predict asphalt mixture moisture
sensitivity started in the 1960s and 1970s with the work of Johnson (1969), Schmidt and Graf
(1972), Jimenez (1974), and Lottman (1978). All recognized the importance of simulating field
conditions through accelerating test conditioning in the laboratory. Jimenez used vacuum
saturation followed by cyclic pore pressure application to achieve this purpose, while Lottman
used vacuum saturation followed by freezing and hot water bath conditioning.
Lottman’s laboratory test protocol, presented to the industry in 1978, was a breakthrough
in regard to a coherent test procedure for predicting moisture-induced damage to asphalt
concrete. The protocol introduced by Lottman was later modified and standardized as AASHTO
Test Procedure T283. Root and Tunnicliff presented their version of the Lottman procedure in
the early 1980s during an extensive evaluation of antistripping additives.
At the same time, Kennedy, Roberts, Anagnos, and Lee at the University of Texas at
Austin introduced two test procedures to the industry: Texas freeze–thaw pedestal test (1982)
and Texas boiling test (1984). The boiling test was developed on the basis of work that had been
conducted in departments of transportation in Louisiana, Texas, and Virginia between 1975 and
1980 and is very similar to the test used by Saville and Axon in 1937. The freeze–thaw pedestal
test was a modification of the procedure introduced earlier by Plancher et al. (1980) at the
Western Research Institute.
Ensley et al. (1984) worked toward development of techniques for measuring the bonding
energy of the asphalt–aggregate system. This was also a time for some researchers to evaluate
the test methods available for moisture damage. As example is the work by Gharaybeh (1987).
Afterwards, there was no significant development in moisture damage test procedures
until the Strategic Highway Research Program (SHRP) sponsored research toward development
of new moisture sensitivity tests. The result of this research was the environmental conditioning
system (ECS) (Al-Swailmi and Terrel 1992). At the same time, the Hamburg wheel-tracking
device (HWTD) was introduced into the United States (Aschenbrener and Currier 1993).
Colorado, Texas, and Utah were among the first states to explore the HWTD (Aschenbrener
1995).
The search for new reliable test procedures for determination of moisture sensitivity
continues. Western Research Institute (WRI) has undertaken in-depth research on asphalt
chemistry and its relationship to moisture damage. WRI has determined that displacement of
asphalt polars from aggregate by water varies by asphalt source. Currently, WRI is developing a
rapid centrifugation method to simulate displacement of polars by water. The hypothesis being
tested is the following: asphalt–aggregate mixtures that form insoluble calcium salts of asphalt
components are the least prone to moisture damage. On another front, the concept of surface
energy has reemerged as a potential tool for determining the adhesion of asphalt–aggregate
systems.
While these recent research developments can contribute significantly toward
determination of compatible and moisture-resistant asphalt–aggregate mixtures, they do not
address the effect of the interaction between traffic and water on moisture damage in pavements.
Hence, a new test procedure on compacted samples is being investigated under National
80 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Cooperative Highway Research Program (NCHRP) Project 9-34 aimed at proper simulation of
environment/traffic factors in regard to moisture damage.
Types of Moisture Sensitivity Tests
In general, the tests that have been developed can be divided into two main categories:
qualitative and quantitative. Qualitative tests provide a subjective evaluation of the stripping
potential and include
Boiling water test,
Freeze–thaw pedestal test,
Quick bottle test,
Rolling bottle method, and
Many others.
The quantitative tests provide a value for a specific parameter such as strength before and
after conditioning. These tests include
Immersion–compression test,
Indirect tensile test,
Marshall immersion test,
Double punch method,
Resilient modulus tests, and
Many others.
Alternatively, the tests can be categorized into those aimed at checking the compatibility
between aggregate and asphalt on the basis of conditioning of the loose mix and those used to
determine moisture sensitivity of the compacted mix structure. The latter can be divided into
those that look at water conditioning and those that include the interaction of traffic and water.
The first type of test helps to determine whether an asphalt–aggregate system is compatible and
whether it is resistant enough against debonding in the presence of water without any attempt to
evaluate the mechanical behavior of the mixture under applied loads and water. In the second
group of tests, attempts are made to take the effect of the compacted mix structure as well as
traffic and environment into consideration when the mix behavior is evaluated in the presence of
water. These tests typically give a result that is interpreted as pass or does not pass. At this time,
none of these tests provide information that can be used in a mechanistic-empirical design
framework by providing information on the effect of water on stiffness, and fatigue and rutting
transfer functions.
The complexity of developing test methods to predict moisture damage in the field is
evident from the variables that interact in this phenomenon, including the following:
The great number of aggregate sources and their highly varied mineralogies, crystal
structures, and surface textures;
The numerous types of unmodified and modified asphalt binders used across the
United States; and
The varied environmental conditions, traffic, and construction practices.
Solaimanian, Harvey, Tahmoressi, and Tandon 81
It has remained a challenge to the pavement industry to improve the current moisture
damage tests to provide a more reliable distinction between poor and good performers and to
relate the numbers from any test to performance on a given project with its unique combination
of variables.
For a moisture susceptibility test procedure to be successful for mix design and field
quality control, certain criteria must be satisfied:
1. It must be representative of the mechanisms that cause moisture damage in the field
and produce results that match those occurring in the field under similar conditions, or it must
measure some property that determines the performance of the mix in the field without actually
simulating field conditions in the laboratory.
2. It must be capable of discriminating between poor and good performers in regard to
stripping. If the first criterion (above) cannot be satisfied, then some discriminator of this type is
useful; however, the results must still be tied to field performance.
3. It must be repeatable and reproducible, with the allowable variance depending on the
constraint of the fourth criterion.
4. It must be feasible, practical, and economical enough that it can be included in routine
mix design practice.
These four criteria are the key items to the success of any test procedure selected for
identification of asphalt concrete moisture susceptibility.
SIGNIFICANCE OF MO ISTURE-SENSITIVITY TESTS
Implementation of any laboratory test for moisture sensitivity or stripping will always require
calibration of the results that the test generates with observed field performance. If the test results
are not calibrated with field performance, the test runs a larger risk of eliminating mixes that
would perform well in the field or permitting mixes that have a high probability of having a
shortened life due to moisture damage.
Review of the literature, including laboratory experiments and field studies, indicates that
while moisture damage susceptibility is highly correlated with aggregate source, other variables
can significantly increase or decrease the risk of moisture susceptibility for a given mix used on a
given project. These variables include (Harvey et al. 2002)
Drainage and the condition of the drainage system;
Pavement structure, including lack of bonding between asphalt concrete layers, which
can permit lateral movement of water; the presence of cracks, which permit water to enter; the
presence of open-graded or seal coat materials below the surface, which can trap water below the
surface; and the presence of fabrics or interlayers that can trap water below the surface;
Mix design, including binder content, gradation, and dust-to-asphalt ratio, which can
determine the film thickness on the aggregates and the permeability of the mix; binder selection,
which determines the stiffness of the binder and the susceptibility to penetration of the asphalt
film by water; and the use of additives, which can reduce the overall susceptibility of the mix;
Construction variability, including segregation, which can create areas with high air
void contents and low binder contents, which permit water to enter and are more susceptible to
moisture damage; variance from the job mix formula, which can create susceptible areas with
82 Moisture Sensitivity of Asphalt Pavements: A National Seminar
less dense gradation and lower binder contents; and compaction, which can create areas with
high air voids and therefore high permeability and low strength;
Climate, which determines the presence of water (unless there is a nearby irrigation or
sprinkler system that is creating an artificial climate), the amount of freeze–thaw action, and the
temperature of the asphalt and the water when it is being subjected to traffic; and
Traffic, which applies stresses to the mix while it is in a weakened condition from
moisture and has been shown in several studies to determine whether moisture damage and
stripping occur by comparison of cores from the wheelpath with those from outside the
wheelpath.
The interactions of these variables and the different level of interaction at which
laboratory test methods can measure relevant properties or simulated performance are shown in
Figure 1.
With regard to the last item in the list, the influence of traffic loading on moisture
damage was recognized early when a forensic analysis was conducted after one of the loading
cycles at the Penn State Test Track. The HMA in the base course was completely stripped of
binder in the wheel tracks but was undamaged between the wheel tracks, as reported by
Anderson and Shamon (1984). Bejarano and Harvey (2002) found that an asphalt-treated
permeable base material stripped completely in the wheelpath in a full-scale pavement subjected
to subsurface water infiltration under heavy vehicle simulator loading but had no stripping just
outside the wheelpath. Some reduction in stiffness and strength was observed in the material
outside the wheelpath.
The preceding list of variables suggests that a “one size fits all” approach in terms of
passing and failing results from laboratory tests will be difficult to implement because a given
mix may perform well under one set of circumstances and poorly under a different set.
Implementation of laboratory tests will be less difficult and the risk of eliminating usable mixes
and permitting susceptible mixes will be reduced if the field calibration is as comprehensive as
possible in terms of consideration of these variables. This should be achieved in the light of a
common test calibrated to local conditions. Some researchers such as Philips and Marek (1986)
have emphasized the need for a moisture damage test via a common procedure.
There are three primary difficulties in performing a comprehensive field calibration:
Obtaining comprehensive data for the independent variables listed above;
Quantifying the dependent variable, performance; and
Relating results from laboratory- and field-compacted test specimens.
In regard to obtaining comprehensive data for the independent variables, most states have
a great deal of difficulty in compiling good data for the independent variables listed above to
relate to observed field performance. In particular, only a few state pavement management
system databases include mix information, construction quality data, or information on the
underlying pavement structure. Very few agencies have information on maintenance activities
that have been performed, which may significantly affect the performance of the pavement with
respect to moisture sensitivity and stripping. The most recent comprehensive efforts at field
calibration have typically included fewer than 25 test sections (Aschenbrener et al. 1995;
Busching et al. 1986) and have not considered the full range of variables shown above.
Solaimanian et al. (1993) evaluated long-term stripping performance of 46 test sections on 9
Solaimanian, Harvey, Tahmoressi, and Tandon 83
FIGURE 1 Factors influencing moisture damage of asphalt pavements (after Lu 2003).
roads for a period of 6 years and found no clear relationship between laboratory results and field
performance.
In addition, the conditions under which moisture damage and stripping occur may not be
the same in different locations. This indicates that calibration data sets must include the climate
regions and traffic conditions in which the test results will be used. For example, Aschenbrener
identified that all of the test sections compared with test results in Colorado had most of their
precipitation during the hottest months of the year. The pass/fail values developed in Colorado
may not be applicable to northeastern California, where the hottest months have little or no
rainfall. The Long-Term Pavement Performance database has not been mined for moisture
sensitivity/stripping information, but it has had difficulty in providing comprehensive data for
many of its test sections. A recent database of hot-mix asphalt concrete data developed by White
et al. (2002) that is comprehensive in terms of the variables listed above may provide a valuable
Field performance of asphalt pavement
Construction
Quality
Pavement
Structure
Traffic (load,
repetition)
Climate (rainfall,
temperature,
FTC)
Resistance of asphalt mixture to moisture damage
under a specific laboratory testing condition
Asphalt-aggregate bonding strength under a specific laboratory testing condition
Air void
structure
Asphalt
content
Aggregate
gradation,
fine content
Asphalt-aggregate interaction through models of
bonding between asphalt and aggregate
Asphalt physicochemical properties
Aggregate physicochemical
properties
Adsorption /
desorption of
functionalities
Additives
content
Impurities
Mineralogical
composition,
surface energy
Surface
texture
Level 3
Level 2
Level 1-2
Level 1
Compacted
mix in
field under
traffic
Compacted mix
conditioned with
water and/or traffic
in the laboratory
Loose mix con-
ditioned with
water
Mix
components
84 Moisture Sensitivity of Asphalt Pavements: A National Seminar
source of information for calibration in the future. Development of better databases for
calibration of laboratory results with field data is vital for development of better laboratory tests
for moisture sensitivity/stripping and other distress mechanisms.
With regard to quantifying performance, identification of stripping can be difficult
without coring if it occurs below the surface, and moisture damage that does not proceed to
stripping is very difficult to identify without information about mix performance in the absence
of water. For example, Aschenbrener et al. (1995) identified pavements as being “good,” “high
maintenance,” “complete rehabilitation,” or “disintegrators.” Pavements were placed in these
categories on the basis of years to failure versus design life and coring to find stripping. Other
researchers use different criteria for all but the “good” pavements. Stripping is seldom formally
identified and entered into a database on field projects when they fail, and the stripping itself is
visually identified and therefore somewhat subjective unless most of the asphalt has disappeared
from the aggregate. This is also the case for laboratory tests that rely on visual identification.
Pavements that do not exhibit significant visible stripping may have their performance
significantly reduced and fail by fatigue cracking, raveling, or rutting, without being identified in
the field as having moisture damage. This makes it difficult to set thresholds for laboratory test
results to minimize moisture damage for mixes that exhibit little observable stripping. Some
laboratory tests also submit the mix to conditions that will not result in stripping but that do
cause significant moisture damage, measured as reduction in strength or stiffness. These tests are
particularly difficult to calibrate with field results because field measurements of stiffness and
strength are difficult to obtain. Mixes lose strength and stiffness when wet but regain these
properties when dried (Figure 2). A faster damage rate occurs under loading when the mix is wet,
but if properties are measured when dry the effects of water may not be apparent.
With regard to the difficulty in relating field and laboratory results, the primary problems
are differences between field and laboratory test specimen air void contents, size of voids,
permeability, and aging. Many of the test methods summarized in this document require that
specimens be prepared to a predetermined air void content. Laboratory studies have shown that
air void content has a significant effect on test results, and difficulty should be expected in
FIGURE 2 Effect of moisture on resilient modulus may be
reversible (after Schmidt and Graf 1972).
Solaimanian, Harvey, Tahmoressi, and Tandon 85
correlating laboratory test results with field performance if laboratory specimens are not
compacted to the same air void contents as occurred or are expected to occur in the field for a
given project. Even when air void contents are matched between the laboratory and field, the
results may vary between the two for the reasons described above, as was identified by
Aschenbrener (1995). These differences will largely depend on the laboratory compaction device
used, because different compaction methods can create very different aggregate and void
structures in the specimen even though the total air void content is the same. The results also
depend on the laboratory aging procedures used.
If a method can be calibrated with field results, the next criteria it must pass to be
implementable concern repeatability and reproducibility and cost in terms of staff, time,
materials, and equipment. To some degree, inherent higher variance can be overcome with
additional replicate specimens. However, bias and variance caused by differences among
operators and laboratories are difficult to overcome with more replicates because the ability to
“tweak” the results is placed in doubt, whether intentionally or unintentionally. These factors
must be considered and be acceptable for a test to be implementable. However, it can be argued
that having a test that is easy and inexpensive to perform but that cannot be calibrated with field
results is of no use.
In addition to an ability to correlate with field performance, laboratory tests are often
required to be able to measure the effects of moisture sensitivity mitigation measures,
particularly additives and modified binders. The effects of mitigation must be correlated with
field performance. Again, the mechanism used in the laboratory to evaluate a mix and its relation
to the mechanism that causes moisture susceptibility/stripping in the field may not be the same,
and as noted previously the field mechanism may vary between different projects.
MOISTURE SENSITIVITY TESTS
Tests used to estimate moisture sensitivity of HMA can be classified into two general types: tests
on loose mixtures and tests on compacted mixtures. Tables 1 and 2 summarize the tests for
moisture sensitivity on loose and compacted mixtures, respectively.
TABLE 1 Moisture Sensitivity Tests on Loose Samples
Test ASTM AASHTO Other
Methylene blue Technical Bulletin 145, International
Slurry Seal Association
Film stripping (California Test 302)
Static immersion D1664* T182
Dynamic immersion
Chemical immersion Standard Method TMH1 (Road
Research Laboratory 1986, England)
Surface reaction Ford et al. (1974)
Quick bottle Virginia Highway and Transportation
Research Council (Maupin 1980)
Boiling D3625 Tex 530-C
Kennedy et al. 1984
Rolling bottle Isacsson and Jorgensen, Sweden, 1987
Net adsorption SHRP A-341 (Curtis et al. 1993)
Surface energy Thelen 1958, HRB Bulletin 192
Cheng et al., AAPT 2002
Pneumatic pull-off Youtcheff and Aurilio (1997)
* No longer available as ASTM standard.
86 Moisture Sensitivity of Asphalt Pavements: A National Seminar
TABLE 2 Moisture Sensitivity Tests on Compacted Specimens
Test ASTM AASHTO Other
Moisture vapor susceptibility California Test 307
Developed in late 1940s
Immersion–compression D1075 T165 ASTM STP 252 (Goode 1959)
Marshal immersion Stuart 1986
Freeze–thaw pedestal test Kennedy et al. 1982
Original Lottman indirect
tension
NCHRP Report 246 (Lottman 1982);
Transportation Research Record 515
(1974)
Modified Lottman indirect
tension
T 283 NCHRP Report 274 (Tunnicliff and Root
1984), Tex 531-C
Tunnicliff–Root D 4867 NCHRP Report 274 (Tunnicliff and Root
1984)
ECS with resilient modulus SHRP-A-403 (Al-Swailmi and Terrel
1994)
Hamburg wheel tracking 1993
Tex-242-F
Asphalt pavement analyzer
ECS/SPT NCHRP 9-34 2002-03
Multiple freeze–thaw
The third category is tests for surface treatments and chip seals.
The following sections provide detail on these tests and their limitations.
Tests on Loose Mixtures
These are the tests conducted on asphalt-coated aggregates in the presence of water. Examples
include boil, film strip, and static/dynamic immersion tests. One advantage of these tests is that
they are simpler and less costly to run than tests conducted on compacted specimens. Another
advantage is that they require simpler equipment and procedures.
The major disadvantage is that the tests are not capable of taking the pore pressure, traffic
action, and mix mechanical properties into account. The results are mostly qualitative, and
interpretation of the results becomes a subjective matter depending on the evaluator’s experience
and judgment. There is also not much evidence correlating results from these tests to field
performance of hot-mix asphalt concrete.
Loose mixture tests are best used for comparison between different aggregate–asphalt
mixtures in terms of compatibility, strength of adhesion, and stripping. Mixtures failing in these
tests, on the basis of some established criterion, have the potential to strip and should be avoided.
However, good results should not mean that a mix can be used, since the effects of the other
contributing factors are not considered in these tests. Defining a pass/fail criterion is not an easy
task for most of these tests. For example, visual evaluation is used in the static immersion test to
determine the degree of stripping below or above 95 percent, a criterion that is not very
repeatable between different operators and different laboratories.
Methylene Blue Test
The methylene blue test attempts to identify the harmful clays and dust available in the fine
aggregate. This test does not directly provide a measure of stripping since no asphalt is used.
Solaimanian, Harvey, Tahmoressi, and Tandon 87
However, the results can be used to decide whether potential for stripping exists because if
aggregates are coated with montmorillonite-type clay, proper coating will not take place between
the aggregate and asphalt.
The methylene blue test was developed in France and was recommended by the
International Slurry Seal Association (ISSA) to quantify the amount of harmful clays of the
smectite (montmorillonite) group, organic matter and iron hydroxides present in fine aggregates.
The test method titled “Determination of Methylene Blue Adsorption Value (MBV) of Mineral
Aggregate Fillers and Fines” was contained in Technical Bulletin 145 of ISSA (1989). In the
test, methylene blue (MB) is dissolved in distilled water with a known concentration. A known
weight of the filler finer than 75 microns is also uniformly stirred and dispersed in a separate
beaker. Drops of MB solution, 0.5 mL each, are added to the solution with a burette one at a time
while stirring. After each drop of MB, one drop of the solution is removed using a stirring rod
and placed on filter paper. The test is continued until a light blue halo is formed around the drop.
The absorption of MB by clay is used to determine the amount of harmful clay, with greater
absorption indicating larger amounts of harmful clays. Research by Kandhal et al. (1998) has
indicated that larger MB values correspond to lower tensile strength ratios from AASHTO T283.
Film Stripping Test (California Test 302)
This is a modified version of test procedure AASHTO T182 (Coating and Stripping of Bitumen–
Aggregate Mixtures). In California Test 302, a 60-g mass of aggregate coated with asphalt is
placed in a 60°C oven for 15 to 18 h. The sample is then cooled to room temperature and placed
in a jar with about 175 mL of distilled water. The jar is securely capped and placed in the testing
apparatus, which rotates at a rate of about 35 rpm for 15 min (Figure 3). The sample is removed
and the percentage of stripping is estimated when the jar is viewed under fluorescent light. The
results are reported in terms of the percent total aggregate surface stripped.
Static Immersion Test (AASHTO T182)
Although this test is still continued as a standard method under AASHTO, it is no longer
available as an ASTM standard (originally ASTM Standard Practice D1664). The asphalt–
aggregate mixture is cured for 2 h at 60°C and cooled to room temperature. It is then placed in a
glass jar and covered with 600 mL of distilled water. The jar is capped and placed in a 25°C
water bath and left undisturbed for 16 to 18 h. The amount of stripping is visually estimated on
Asphalt Coated
Aggregate
and Water
Capped Jar
FIGURE 3 Rotating asphalt–aggregate mixture in a sealed jar for film stripping test.
88 Moisture Sensitivity of Asphalt Pavements: A National Seminar
the basis of the established criteria. The total visible area of the aggregate is estimated as either
less than or greater than 95%. This is a major limitation of the test because the results are
decided purely on the basis of a subjective estimate of less than or greater than 95%. Test results
have indicated that placing samples at 60° C bath rather than 25° C for 18 h increases the amount
of stripping.
Dynamic Immersion Test
The dynamic immersion test is used to accelerate the stripping effect compared with the static
immersion test. The test has not been standardized and is not widely used. Samples of asphalt–
aggregate mixtures are prepared the same way as for the static immersion test but are subjected
to 4 h of agitation. As the period of agitation increases, the degree of stripping increases. Both
static and dynamic immersion tests, however, fail to take into account the pore pressure effect
and traffic action, as is the case for all tests on loose mixtures.
Chemical Immersion Test
The chemical immersion test method covers the determination of the adhesion of bitumen to
stone aggregate by means of boiling asphalt-coated aggregate successively in distilled water.
Increasing concentrations of sodium carbonate (Na
2
CO
3
) are used, numbered 0 to 9 and referred
to as the Riedel and Weber (R&W) number. Zero refers to distilled water, 1 implies 0.41 g of
sodium carbonate in 1 L of water, and 9 refers to the highest concentration, which is 106 g of
Na
2
CO
3
in 1 L of water. Between 1 and 9, for every doubling of concentration the R&W number
is increased by one. The number of the concentration at which the bitumen strips to such an
extent that it is no longer a film but only specks or droplets is called the stripping value.
An asphalt–aggregate test sample of 100 g is dried in an oven at 110°C. The aggregate is
mixed with binder at high temperature and left to cool to room temperature. Solutions of sodium
carbonate in distilled water are prepared at different concentrations. About 50 mL of distilled
water is brought to boiling in a 200-mL glass beaker. Afterwards, 10 g of the prepared
aggregate–binder mix is placed into the boiling water. After 1 min of boiling, the water is
drained and the sample is placed on filter paper. The sample is examined for stripping after it is
dry. The stripping value of the aggregate is the R&W number of the lowest concentration at
which stripping occurs. If the sample does not strip at number 9, a stripping value of 10 is given
to the aggregate. If no stripping is observed, the procedure is repeated, starting with the weakest
concentration of sodium carbonate.
Surface Reaction Test
Test procedures have been developed at different times to quantify the level of stripping for
loose asphalt–aggregate mixtures. Quantifying the degree of stripping eliminates problems
encountered with visual rating. One of these procedures, developed by Ford et al. (1974), is
called the surface reaction test. This test is based on the principle that calcareous or siliceous
minerals will react with a suitable reagent and create a gas as part of the chemical reaction
products. This generated gas, in a sealed container, will create a certain pressure that can be
considered proportional to the mineral surface area exposed to the reagent. The reagent is
typically an acid. The test is conducted on the asphalt–aggregate mixture after it has been
subjected to the stripping effects of water. Different levels of stripping result in different exposed
surface areas of aggregate particles. A larger exposed surface area will generate higher gas
Solaimanian, Harvey, Tahmoressi, and Tandon 89
pressure. The advantages of the test are that it is simple and reproducible and takes less than 10
min to perform. A disadvantage is that the test requires use of highly corrosive and toxic acids.
Texas Boiling Test
The Texas boiling test procedure was developed by Kennedy et al. (1982; 1984) on the basis of
the earlier work. The procedure requires adding asphalt–aggregate mixture to boiling water and
bringing the water back to boiling after this addition. After 10 min, the mixture is allowed to cool
while the stripped asphalt is skimmed away. The water is drained, and the wet mixture is placed
on a paper towel and allowed to dry. Visual rating is conducted to assess the level of stripping.
This test procedure is a quick method for evaluating the moisture sensitivity of an asphalt–
aggregate mixture. However, it does not account for mechanical properties of the mix, and it
does not include the effects of traffic action. The test is also subjective and qualitative, and
results are judged on the basis of a visual rating. A useful application of the test could be for
quick evaluation of various asphalt–aggregate combinations as a relative measure of the bond
quality and stripping resistance. The procedure has been standardized as ASTM D3625 (Effect of
Water on Bituminous-Coated Aggregate Using Boiling Water).
Rolling Bottle Test
The test was developed by Isacsson and Jorgensen of Sweden (1987). Aggregate chips are coated
with binder and covered with water in glass jars. The jars are rotated so that the contents are
agitated. Periodically, the coating of the stones is estimated visually.
Net Adsorption Test
The net adsorption test (NAT) was developed under SHRP in the early 1990s and is documented
in SHRP Report A-341 (Curtis et al. 1993). The test is used to determine the affinity and
compatibility of an asphalt–aggregate pair and the sensitivity of the system to water. Therefore, it
can be considered a screening test.
The test comprises two steps. First, asphalt is adsorbed onto aggregate from a toluene
solution, the amount of asphalt remaining in solution is measured, and the amount of asphalt
adsorbed to the aggregate is determined. Second, water is introduced into the system, asphalt is
desorbed from the aggregate surface, the asphalt present in the solution is measured, and the
amount remaining on the aggregate surface is calculated. The amount of asphalt remaining on
the surface after desorption is termed net adsorption.
The net adsorption test offers a direct means of comparing the affinity of different
asphalt–aggregate pairs. The test is relatively fast and easily performed. However, SHRP Report
A-341 provides mixed conclusions in terms of correlation between NAT results and moisture
sensitivity results from indirect tension tests on compacted specimens. The NAT procedure was
modified by researchers at the University of Nevada at Reno, and the test results were correlated
with the ECS (Scholz et al. 1994). The study by Scholz et al. (SHRP-A-402, 1994) indicates that
predictions of the water sensitivity of the binder as proposed by NAT show little or no
correlation to wheel-tracking tests on the mixes.
Wilhelmy Plate Test and Universal Sorption Device for Surface Free Energy
In recent years, asphalt technologists have performed research into the relationship between
surface free energy and moisture damage potential. Most of the surface energy research for
90 Moisture Sensitivity of Asphalt Pavements: A National Seminar
asphalt–aggregate mixture combinations has been conducted at Texas A&M University
(Elphingstone 1997; Cheng et al. 2001; Cheng et al. 2002).
The principle behind using the concept of surface free energy is that the cohesive bonding
within asphalt and the adhesive bonding between asphalt and aggregate are related to the surface
free energy of the asphalt and aggregate. Researchers at Texas A&M University demonstrated
the effectiveness of this concept by using three different aggregates (one granite and two
limestone aggregates) and two of the SHRP asphalts (AAM and AAD). The permanent
deformation on compacted specimens using compressive testing correlated well with measured
values of surface free energy of the asphalts and aggregates used in the research when tested in
dry and wet conditions. The asphalt surface free energy is determined by using a Wilhelmy plate
test, where the dynamic contact angle between asphalt and a liquid solvent is measured. The
surface free energy of aggregate is measured by using a universal sorption device developed at
Texas A&M University.
Pneumatic Pull-Off Test
The pneumatic pull-off test provides a rapid and reproducible means of evaluating moisture
susceptibility of asphalt binders. The experimental procedure measures the tensile and bonding
strength of asphalt binder applied to a glass plate as a function of time while exposed to water.
Asphalt binder, containing 1.0% by weight of glass beads, is applied to a porous disk, which is
then pressed onto a glass plate. The glass beads are used to control the thickness of the asphalt
film and do not appear to have any effect on the results. The pressure necessary to debond the
conditioned specimen at 25° C is measured with a pneumatic adhesion tester. The typical pulling
rate is about 66 kPa/s, and asphalt film thickness is around 200 microns. The test has indicated
that, as expected, soak time is an important factor. This means that longer exposure to water
increases stripping damage if the mixture is susceptible to debonding. A study by Youtcheff and
Aurilio (1997) has indicated that the viscosity building structure provided by asphaltenes is
disrupted by the presence of water, and the resistance to moisture damage of the binder appears
to depend on the properties of the maltenes.
Tests on Compacted Mixtures
These tests are conducted on laboratory-compacted specimens or field cores or slabs. Examples
include indirect tensile freeze–thaw cyclic with modulus and strength measurement, immersion–
compression, abrasion weight loss, and sonic vibration tests. This last test is also conducted on
loose mixtures and is currently under investigation by the Western Research Institute. The major
advantage of these tests is that the mix physical and mechanical properties, water/traffic action,
and pore pressure effects can be taken into account. The results can be measured quantitatively,
which minimizes subjective evaluation of test results. The drawback of these tests is that more
elaborate testing equipment, longer testing times, and more laborious test procedures are needed.
Immersion–Compression Test ASTM D1075 (1949 and 1954) and AASHTO T165-55 (Effect of
Water on Compressive Strength of Compacted Bituminous Mixtures)
The immersion–compression procedure was originally published as ASTM D1075-49.
Therefore, the test is among the first to be used for evaluation of moisture sensitivity. Revisions
were made to the procedure in 1996. Goode (1959) explains the test in detail in ASTM Special
Technical Publication 252.
Solaimanian, Harvey, Tahmoressi, and Tandon 91
Two groups of compacted specimens are used in this test method. One group is
submerged in a 120° F water bath for 4 days for conditioning, and the other group is maintained
dry. An alternative approach to conditioning is to immerse the test specimens in water for 24 h at
140° F. Compressive strength is measured on specimens of both groups at 77° F at a deformation
rate of 0.05 in./min per inch of height. For a 4-in.-tall specimen, the rate would be 0.2 in./min.
The average strength of conditioned specimens over that of dry specimens is used as a measure
of moisture sensitivity of the mix. Most agencies have used a 70% ratio as a passing limit.
Marshall Immersion Test
The conditioning phase of this test is identical to the one used for the immersion–compression
test. However, Marshall stability is used as a strength parameter rather than compressive
strength.
Moisture Vapor Susceptibility
The moisture vapor susceptibility procedure was developed and has been used by the California
Department of Transportation (California Test Method 307). Two specimens are prepared and
compacted using the kneading compactor, as for mix design testing, except that they are prepared
in stainless steel molds. The compacted surface of each specimen is covered with an aluminum
seal cap, and a silicone sealant is applied around the edges to prevent the escape of moisture
vapor. An assembly with a felt pad, seal cap, and strip wick is prepared to make water vapor
available to the specimen by placing the free ends of the strip wick in water. After the assembly
is left in an oven at 60° C with the assembly suspended over water for 75 h, the specimen is
removed and tested immediately in the Hveem stabilometer. A minimum Hveem stabilometer
value is required, which is less than that required for the dry specimens used for mix design.
Repeated Pore Water Pressure Stressing and Double-Punch Method
This test procedure was developed by Jimenez at the University of Arizona (1974). The test falls
in the category of those that include measurement of mix mechanical properties and those that
take traffic dynamic loading into account. To capture the water pore pressure effect, compacted
specimens undergo a cyclic stressing under water. The load is not directly in contact with the
specimen. This stressing is accomplished through generating cyclic pressure within water at a
rate of 580 rpm. The generated water pressure is between 35 and 217 kPa, which, according to
Jimenez, is within a range comparable with pressure expected in saturated pavements under
traffic. Once cyclic water pressure inducement is complete, the tensile strength of the specimens
is determined by using the double-punch equipment. Compacted specimens are tested through
steel rods placed at either end of the specimen in a punching configuration. Jimenez
demonstrated the severity of this test by comparing predictions on similar mixtures using the
immersion–compression test.
Original Lottman Indirect Tension Test
The original Lottman procedure was developed by Lottman at the University of Idaho in the late
1970s (Lottman 1978). The procedure requires one group of dry specimens and one group of
conditioned specimens. The specimens are 4 in. in diameter and about 2.5 in. thick. Conditioning
includes vacuum saturation of specimens under 26 in. of mercury vacuum for 30 min followed
by 30 min at atmospheric pressure. The partially saturated specimens are frozen at 0° F for 15 h
followed by 24 h in a 140° F water bath. This is considered accelerated freeze–thaw conditioning.
92 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Lottman proposed thermal cyclic conditioning as an alternative. For each cycle, after 4 h
of freeze at 0° F, the temperature is changed to 120° F and maintained for 4 h before being
changed back to 0° F. Therefore, a complete thermal cycle lasts 8 h. The specimens go through
18 thermal cycles of this type. Lottman concluded that thermal cycling was somewhat more
severe than the accelerated freeze–thaw conditioning with water bath. Conditioned and dry
specimens are both tested for tensile resilient modulus and tensile strength using indirect tensile
equipment. The loading rate is 0.065 in./min for testing at 55° F or 0.150 in./min for testing at
73° F. The severity of moisture sensitivity is judged on the basis of the ratio of test values for
conditioned and dry specimens.
AASHTO T283 (Modified Lottman Indirect Tension Test Procedure)
The AASHTO Standard Method of Test T283, “Resistance of Compacted Bituminous Mixture to
Moisture Induced Damage,” is one of the most commonly used procedures for determining
HMA moisture susceptibility. The test is similar to the original Lottman with a few exceptions.
One of the modifications is that the vacuum saturation is continued until a saturation level
between 70% and 80% is achieved, compared with the original Lottman procedure that required
a set time of 30 min. Another change is in the test temperature and loading rate for the strength
test. The modified procedure requires a rate of 2 in./min at 77° F rather than 0.065 in./min at
55° F. A higher rate of loading and a higher temperature were selected to allow testing of
specimens with a Marshall stability tester, available in most asphalt laboratories. The higher
temperature also eliminates the need for a cooling system.
Briefly, the test includes curing loose mixtures for 16 h at 60° C, followed by a 2-h aging
period at 135° C. At least six specimens are prepared and compacted. The compacted specimens
should have air void contents between 6.5% and 7.5%. Half of the compacted specimens are
conditioned through a freeze (optional) cycle followed by a water bath. First, vacuum is applied
to partially saturate specimens to a level between 55% and 80%. Vacuum-saturated samples are
kept in a –18° C freezer for 16 h and then placed in a 60° C water bath for 24 h. After this period
the specimens are considered conditioned. The other three samples remain unconditioned. All of
the samples are brought to a constant temperature, and the indirect tensile strength is measured
on both dry (unconditioned) and conditioned specimens (Figure 4).
Tensile Strength Ratio
80 %
minimum
Conditioned Specimens
Dry Specimens
80 %
minimum
FIGURE 4 Indirect tensile test used for dry and
conditioned specimens for AASHTO T283.
Solaimanian, Harvey, Tahmoressi, and Tandon 93
State highway agencies report mixed success with this method. Several research projects
have dealt with the method’s shortcomings, resulting in suggested “fixes,” but the test remains
empirical and liable to give either false positives or false negatives in the prediction of moisture
susceptibility. Major concerns with this test are its reproducibility and its ability to predict
moisture susceptibility with reasonable confidence (Solaimanian and Kennedy 2000a).
AASHTO T283 was adopted by the Superpave system as the required test for
determination of moisture damage. Following this adoption, state highway agencies made this
test the most widely used procedure for determination of moisture damage potential. Later, Epps
et al. (2000) investigated this test extensively under NCHRP Project 9-13. The project,
“Evaluation of Water Sensitivity Tests,” was completed in 1999 and provided recommended
changes to AASHTO T283 to better accommodate its use in the Superpave system. The
researchers investigated the effect of a number of factors on the test results, including different
compaction types, diameter of the specimen, degree of saturation, and the freeze–thaw cycle.
They used five aggregates, two considered good performers in terms of moisture resistance and
the other three considered to have low to moderate resistance to moisture damage. Binders were
specific to each mix and included PG 58-28, 64-22, 64-28, and 70-22. In summary, the following
conclusions were drawn from that study, as reported by Epps et al. (2000):
In general, resilient modulus had no effect on tensile strength of dry specimens,
conditioned specimens with no freeze–thaw, or conditioned specimens with freeze–thaw.
Dry strength of 100-mm-diameter Superpave gyratory compactor (SGC) specimens
and 100-mm Hveem specimens was larger than that of 150-mm SGC specimens.
Dry strength of 100-mm Marshall specimens was the same as that of the 150-mm
SGC specimens.
Dry strength of 100-mm-diameter SGC specimens was similar to the dry strength of
100-mm Hveem specimens.
Dry strength increased as the aging time for the loose mix increased.
The freeze–thaw tensile strength was the same as the no freeze–thaw tensile strength.
The level of saturation had little effect on the no freeze–thaw and freeze–thaw tensile
strengths. The levels of saturation used in the study were 50%, 75%, and 95%.
The tensile strength ratio of 150-mm SGC specimens was larger than the tensile
strength ratio of 100-mm-diameter SGC specimens or 100-mm Hveem specimens.
The tensile strength ratio of 150-mm SGC specimens was similar to the tensile
strength ratio of 100-mm Marshall specimens.
The results obtained in this study indicated that the water sensitivities of the mixtures as
described by the state departments of transportation did not satisfactorily match the observed
behavior of the mixtures for a number of data groups.
ASTM D4867 (Tunnicliff–Root Test Procedure)
ASTM D4867, “Standard Test Method for Effect of Moisture on Asphalt Concrete Paving
Mixtures,” is comparable with AASHTO T283. In both methods, the freeze cycle is optional.
However, curing of the loose mixture in a 60°C oven for 16 h is eliminated in the ASTM D4867
procedure.
94 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Texas Freeze–Thaw Pedestal Test
The Texas freeze–thaw pedestal test was proposed by Kennedy et al. (1982) as a modification of
the water susceptibility test procedure proposed by Plancher et al. (1980) at the Western
Research Institute. The test is in the category of those evaluating the compatibility between
asphalt binder and aggregate and the corresponding adhesiveness.
The test is designed to minimize the effect of mechanical properties of the mix by using a
uniform-sized aggregate. It prescribes the preparation of hot mix using a fine fraction of
aggregate [passing the No. 20 (0.85-mm) and retained on the No. 35 (0.50-mm) sieve] and
asphalt at a temperature of 150° C. The hot mix so prepared is kept in the oven at 150° C for 2 h
and stirred for uniformity of temperature every hour. At the end of 2 h, the mix is removed from
the oven and cooled to room temperature, reheated to 150° C, and compacted with a load of about
28 kN for 15 min to form a briquette 41 mm in diameter by 19 mm in height (the procedure does
not prescribe any tolerance for the dimensions). The briquette is cured for 3 days at room
temperature and placed on a pedestal in a covered jar of distilled water (Figure 5). It is then
subjected to thermal cycling of 15 h at –12° C, followed by 9 h at 49° C. After each cycle, the
briquette surface is checked for cracks. The number of cycles required to induce cracking is a
measure of water susceptibility (typically 10 freeze–thaw cycles).
Pedestal test specimens are prepared from a narrow range of uniformly sized aggregate
particles coated with 5% asphalt. This formulation reduces aggregate particle interactions in the
mixture matrix, and the thin asphalt coating between aggregate particles produces a test
specimen that is highly permeable and thus allows easy penetration of water into the interstices
found between aggregate particles. Therefore, moisture-induced damage in the specimen can
easily arise either from bond failure at the asphalt–aggregate interface region (stripping) or from
the fracture of the thin asphalt–cement films bonding aggregate particles (cohesive failure) by
formation of ice crystals.
FIGURE 5 Freeze–thaw pedestal test: compacted specimen
in a water jar ready for thermal cycling.
Specimen (Briquette)
Stress Pedestal
Jar
Cap
Wate
r
Solaimanian, Harvey, Tahmoressi, and Tandon 95
Hamburg Wheel-Tracking Device
The HWTD was developed by Esso A.G. in the 1970s in Hamburg, Germany (Romero and
Stuart 1998). This device measures the combined effects of rutting and moisture damage by
rolling a steel wheel across the surface of an asphalt concrete specimen that is immersed in hot
water. The wheel rolls back and forth on the submerged specimen. Originally, a pair of cubical
or beam test specimens were used. However, with the increasing use of the SGC, the Texas
Department of Transportation (TxDOT) and others have adopted a testing protocol using
cylindrical specimens compacted in the SGC (Figure 6). Typically, gyratory-compacted
specimens are arranged in a series to provide the required path length for the wheels. Each steel
wheel passes 20,000 times or until 20 mm of deformation is reached. The measurements are
customarily reported versus wheel passes.
The results from the HWTD are the postcompaction consolidation, creep slope, stripping
slope, and stripping inflection point (Figure 7). The postcompaction consolidation is the
deformation measured at 1,000 passes, assuming that the wheel is densifying the mixture within
the first 1,000 wheel passes. The creep slope is the number of repetitions or wheel passes to
create a 1-mm rut depth due to viscous flow. The stripping slope is represented by the inverse of
the rate of deformation in the linear region of the deformation curve, after stripping begins and
until the end of the test. The stripping slope can be quantified as the number of passes required to
create a 1-mm impression from stripping. The stripping inflection point is the number of passes
at the intersection of the creep slope and the stripping slope. It represents the moisture damage
resistance of the HMA and is assumed to be the initiation of stripping (Aschenbrener and Currier
1993).
FIGURE 6 HWTD with cylindrical specimens.
96 Moisture Sensitivity of Asphalt Pavements: A National Seminar
-25
-20
-15
-10
-5
0
00.511.522.5 3 3.5 4
Cycles (x1000)
Permanent Deformation (mm)
Note:
Postcompaction
Creep Slope
Stripping Slope
Stripping Inflection Point
FIGURE 7 Results from testing with the HWTD.
This device has been researched extensively through a series of projects (Aschenbrener
and Currier 1993; Aschenbrener 1995; Stuart and Izzo 1995; Stuart and Mogawer 1995;
Aschenbrener et al. 1995; Stuart and Mogawer 1997). The Federal Highway Administration
(FHWA) has been involved in several research projects using the HWTD. Stuart and Izzo (1995)
worked on finding a correlation between binder stiffness and rutting susceptibility using the
HWTD. They found that a stiffer binder would provide a mixture with lower rutting
susceptibility. Stuart and Mogawer (1995), using different binders, concluded that the creep
slopes should be used for evaluating rutting susceptibility. The researchers also demonstrated
that decreasing the coarse aggregate content from 80% to 60% had no significant effect on the
rutting performance of the mixtures.
Stuart and Mogawer (1997) also performed a study to evaluate the validity of laboratory
wheel-tracking devices on the basis of pavement performance results. They concluded that the
increase in nominal maximum size from 19 mm to 37.5 mm, and an associated 0.85% decrease
in optimum binder content, decreased rutting susceptibility on actual pavements. However, none
of the wheel-tracking devices tested, including the HWTD, adequately predicted a decrease in
rutting susceptibility with increased nominal maximum aggregate size.
The Colorado Department of Transportation (CDOT) has performed extensive research
evaluating HMA with the HWTD. Aschenbrener (1995) evaluated factors that influence the
results from the HWTD. He found that there was an excellent correlation between stripping
observed in laboratory tests and the moisture damage of pavements with known field
performance. There was also an excellent correlation between stripping inflection point and
known stripping performance.
It was found that for good pavements, the stripping inflection point was higher than
10,000 passes, and for pavements that lasted 1 year, the stripping inflection point was less than
3,000 passes. It was also found that the results from the HWTD were sensitive to aggregate
properties such as dust coating on the aggregates, clay content, and high dust-to-asphalt ratios.
One other finding was that as the short-term aging time increases, samples become more
resistant to moisture damage. This is in agreement with other research that shows that higher mix
stiffness for conventional binders generally gives better stripping results (because water
Solaimanian, Harvey, Tahmoressi, and Tandon 97
penetration will be more difficult). Aschenbrener recommended that testing temperatures for the
HWTD be selected on the basis of the high temperature environment the pavement will
experience.
Although it is used in the asphalt industry primarily as a screening test for moisture
sensitivity, the HWTD test has also shown promise in providing information on aggregate
properties (Solaimanian and Kennedy 2000b). In spite of its utility as a screening test, a
disadvantage is that this test does not provide a fundamental property that can be used for
modeling purposes. Recommended values for specific climates and traffic levels are also not
available. The test also simulates the stripping mechanism that takes place when rainfall occurs
during the hot time of the year, hence Aschenbrener’s recommendation that test temperatures
should be selected from the hottest time of the year. This recommendation may not be applicable
to locations where water primarily enters the asphalt concrete during the cooler time of the year.
Environmental Conditioning System
As part of the SHRP Asphalt Research Program, the mechanisms responsible for moisture
damage were extensively investigated, and a new system for predicting the moisture
susceptibility of HMA was developed (Al-Swailmi and Terrel 1992). The ECS test procedure
was developed at Oregon State University (OSU) as a part of the Asphalt Research Program. The
procedure (originally designated as AASHTO TP34, “Determining Moisture Sensitivity of
Compacted Bituminous Mixtures Subjected to Hot and Cold Climate Conditions”) was designed
to determine the moisture susceptibility of compacted HMA specimens under conditions of
temperature, moisture saturation, and dynamic loading similar to those found in pavements. A
schematic diagram of the ECS is shown in Figure 8.
In this procedure, a membrane-encapsulated specimen is subjected to cycles of
temperature, repeated loading, and moisture conditioning. The specimens used in the ECS
procedure are 102 ± 4 mm in diameter and 102 ± 4 mm in height. The air void content of the test
specimens must be in the range of 7.5% ± 0.5% (note that AASHTO T283 requires 7.0% ±
0.5%). The loose asphalt concrete mixtures are prepared following AASHTO TP4-93, Edition
1B, and are short-term aged in accordance with AASHTO PP2-94, first edition. The short-term
FIGURE 8 Schematic diagram of the ECS test.
98 Moisture Sensitivity of Asphalt Pavements: A National Seminar
aged mixtures are compacted using an SGC per AASHTO TP4-93. The compacted specimens
are left at room temperature overnight to cool to room temperature. Afterwards, a latex
membrane is placed around the specimen and sealed with a silicone sealant. The specimens are
then set aside for a minimum of 15 h to dry.
The air permeability and dry resilient modulus (M
R
) of the specimen are determined after
it is placed inside the ECS load frame. The air permeability is determined by flowing air through
the specimen at a vacuum level of 68 kPa. The resilient modulus is determined by applying a
load in the form of a haversine wave with a loading period of 0.1 s and a rest period of 0.9 s.
Pulling deaired distilled water through it at a vacuum level of 68 kPa then saturates the
specimen. In the next step, the water permeability of the specimen is determined.
The saturated specimen is subjected to a “hot cycle,” that is, the temperature of the
specimen is elevated to 60° C for 6 h while it is subjected to the haversine loading. The specimen
is cooled to a temperature of 25° C for at least 2 h. At the end of the 8 h, the conditioned M
R and
the water permeability are determined. The process is repeated for two more cycles (i.e., 6 h of
loading and heating at 60°C followed by 2 h of cooling). If the ratio of the conditioned MR to the
unconditioned M
R
falls below 0.7, the mixture is considered as moisture susceptible; if the ratio
is greater than 0.70 the mixture is considered acceptable. Needless to say, this procedure is too
long and complicated and must be shortened and simplified before it can be adopted for routine
mixture design or quality control testing.
One advantage of the ECS is that it includes the influence of traffic loading and the
resulting effect of pore water pressure, a significant consideration if the mechanism that causes
moisture damage in the pavement is to be simulated.
The ECS showed promise when it was introduced to the industry. One of the main
advantages of the system was its capability of simulating field conditions within the laboratory to
some extent. The test setup had the capability of applying load while the specimen was at
elevated temperature and saturated. Lottman (1971), Majidzadeh and Brovold (1966), Anderson
and Shamon (1984), Hallberg (1950), and Jimenez (1974) have suggested that one of the
mechanisms of stripping is the inducement of pore pressure within the air voids of HMA due to
traffic and temperature loads. They proposed that pore water pressure could exceed the adhesive
strength of the binder aggregate surface and break the adhesive bonds. The researchers at OSU
tried to simulate this mechanism by applying a repeated load on the specimen while the saturated
specimen was heated. However, the visual stripping, permeability, and modulus measurements
from AASHTO TP34 did not provide a better relationship with field observations than what was
obtained from AASHTO T283. In addition, the test was more complex and expensive than the
other tests existing at the time.
One of the first studies in which the ECS and the HWTD were evaluated includes the
work conducted by Aschenbrener et al. (1994). The researchers compared the results from the
ECS and the HWTD for 20 pavement sites with known histories of performance with respect to
moisture damage. Performance of the sites was categorized as good, high maintenance, complete
rehabilitation, or disintegrator. Their conclusion was that the HWTD is a very severe test,
especially for the sites with good field performance. The researchers concluded that, with some
modification, the HWTD results correlated well with field performance of the pavements for
which the tests were conducted. With regard to the ECS, the conclusion was that the samples
were only mildly conditioned. Only 3 of the 13 sites with poor field performance failed in the
laboratory.
Solaimanian, Harvey, Tahmoressi, and Tandon 99
Tandon et al. (1997), in a study sponsored by TxDOT, performed a comprehensive
evaluation of the ECS in which special emphasis was placed on the accuracy and precision of the
system. Researchers identified numerous problems with the resilient modulus measurement
systems and conditioning procedures. The original ECS system as proposed by the SHRP
researchers consisted of a pneumatic loading system placed inside a conditioning chamber. The
chamber had the capability of maintaining temperature at 60° C. However, water at room
temperature was supplied to the specimen (for maintaining saturation). This reduced the
temperature of the specimen to 40° C. This cooling of the specimen might affect the proper
conditioning of the specimen. Diverting the flow of water through a heating system before it
reaches the specimen could eliminate this problem. To maintain saturation, water is continuously
pulled through the specimen by using a vacuum. The vacuum also induces confinement to the
specimen and reduces the possibility of specimen bulging during the conditioning phase.
A coefficient of variation of more than 30% was observed during the preliminary
evaluation of the original ECS using 15 HMA specimens (3 types of mixes with 5 specimens of
each mix). To identify causes of variability, the resilient modulus of a synthetic specimen was
measured nine times by dismantling and reassembling the specimen in the test setup. The
observed coefficient of variation was similar to that of the HMA mix, indicating that the problem
was with the test setup. The rigidity of the test setup, vibrations in the measurement system, and
the precision of the strain measurement device were evaluated. Researchers noted that the system
lacked rigidity and had to be replaced with a rigid loading system. The loading system was
placed inside the chamber on a flexible support, contributing to excessive system compliance and
allowing vibrations (due to loading) to be transferred to the strain measurement system. This
resulted in reduction of the precision of the strain measurement system. In addition, the strain
measurement system consisted of yoke assembly and linear variable differential transformer
(LVDT). Researchers ascertained that the yoke assembly significantly affected the repeatability
of the system and needed to be replaced by a more robust strain measurement system.
On the basis of the evaluation and recommendations of the researchers, Alam (1997)
modified the system and proposed the following procedure:
The ECS system consists of a fluid conditioning subsystem, an environmental
conditioning subsystem and a loading subsystem. The fluid conditioning
subsystem maintains a constant flow of water and supply of vacuum to the
specimen. The environmental conditioning subsystem, which houses the loading
subsystem, can maintain a desired temperature and humidity. The loading
subsystem can simulate traffic conditions by applying a repeated half-sine loading
on the specimen throughout the conditioning phase. The same subsystem is also
used for measuring the resilient modulus of the specimen.
The specimen to be tested is prepared at an air void content of between 7%
and 8% with a height of 4 ± 0.15 in. (102 ± 4 mm). The prepared specimen is
removed from the mold and cooled at room temperature for one hour. The
specimen is then subjected to static immersion saturation for five minutes,
enclosed within a membrane, and placed between the top and bottom end platens
of the resilient modulus (MR) test setup. After this step, water at room
temperature is circulated through the specimen for one hour. After one hour of
waiting, the water flow is stopped, the vacuum is released, and the reference
resilient modulus is measured.
100 Moisture Sensitivity of Asphalt Pavements: A National Seminar
The specimen is then conditioned either for six or eighteen hours. During
the conditioning, a flow of water at 140° F (60°° C) is maintained while a cyclic
load is applied to the specimen. After six hours of conditioning, the chamber door
is opened, conditioning is stopped and the circumference of the specimen is
measured. If the circumference of the specimen increases by more than 2%, the
material will be considered as moisture-susceptible. At this point, the conditioning
process is stopped, and the specimen is removed from the setup. Otherwise, the
specimen is conditioned for twelve additional hours. After the specimen is cooled,
the resilient modulus of the specimen is measured again and is considered as the
conditioned resilient modulus. If the MR ratio (ratio of the conditioned and
unconditioned resilient moduli) falls below 0.8, the mixture will be considered as
marginal. If the MR ratio is equal to or above 0.8, the mixture will be considered
as a well-performing mix.
Tandon and Nazarian (2001) tested three different types of mixes with the ECS: well
performing, poor performing, and marginal performing. The new test setup and protocol were
evaluated by using blind mixes (Tandon and Nazarian 2001). The predicted behavior from the
modified ECS procedure matched field performance in some cases, and in other cases it did not.
A postmortem study indicated that the gradation used in specimen production did not
consistently match the job mix formula. New specimens were prepared as per job mix formula,
and the results matched the anticipated field performance.
This validation study indicates one of the limitations of any moisture susceptibility
laboratory test that relies on mechanical properties. Since the modulus or strength of a material is
dependent on parameters such as the gradation, asphalt concrete content, and air void content,
any deviation from the job mix formula during construction or laboratory testing may favorably
or unfavorably affect the moisture susceptibility of the mixture.
Flexural Fatigue Beams Test with Moisture Conditioning
To evaluate the effects of moisture damage on the fatigue cracking performance of asphalt
concrete mixes, experimentation on moisture conditioning of flexural fatigue beams was done by
Shatnawi et al. (1995). Fatigue beams were cut from field sections that had exhibited different
levels of moisture-related damage. Raw materials from these projects were also used to create
laboratory-compacted fatigue beams, including some with lime treatment added.
The conditioned beams were partially saturated to 60% to 80% by using a vacuum and
then subjected to three repeated 5-h cycles of 60° C followed by 4 h at 25° C while remaining
submerged, and one 5-h cycle at –18° C. They were then removed from the water bath and tested
for fatigue following AASHTO TP-8. The results showed that the conditioning had a significant
effect on the initial stiffness and on the fatigue performance in the laboratory. For the laboratory-
compacted specimens asphalt content and air void content were not independently controlled,
and the results showed that binder contents reduced by 0.5% produced higher air void contents
under standard compaction, which together increased the moisture susceptibility of both initial
stiffness and fatigue life.
Some of the specimens obtained from the field had air void contents greater than 12%,
which indicated that their moisture susceptibility in the field was highly related to construction
compaction control. The results also showed that lime marination treatment improved the
performance of the fatigue beams. Two potential reasons for the benefits of the lime treatment
Solaimanian, Harvey, Tahmoressi, and Tandon 101
could not be separated in the experiment design: the lime increased the fines content of the
mixes, which resulted in lower air void contents under a standard laboratory compaction effort,
and it was assumed that there was a chemically induced benefit as well.
ECS/Simple Performance Tests Procedure
New test procedures such as simple performance tests (SPTs) are emerging as a result of
NCHRP Projects 9-19, 9-29, and 1-37. These tests will fill the gap for the Superpave design
system, which currently lacks mechanical tests as part of the design procedure. The proposed
tests are dynamic modulus, repeated axial load, and static axial creep tests. NCHRP Project 9-34,
currently in progress, is using these tests with the ECS to develop new test procedures for
evaluation of moisture sensitivity (Figures 9 and 10). It is anticipated that modifications to the
current conditioning are required to obtain the most reliable procedure. Below is a brief
description of the three SPTs under evaluation for moisture sensitivity.
Dynamic Modulus To measure dynamic modulus, sinusoidal loads are applied to the specimen
at different test temperatures and test frequencies. A sinusoidal (haversine) axial compressive
stress is applied to a specimen of asphalt concrete at a given temperature and loading frequency.
The applied stress and the resulting recoverable axial strain response of the specimen are
measured and used to calculate the dynamic modulus and phase angle.
In this procedure, a 150- by 150-mm specimen is prepared using an SGC and is cored in
the center to obtain a 100-mm (diameter) by 150-mm (height) specimen. The cored specimen is
sawed at the ends to make leveled specimens. The gauge length for measuring axial
deformations is 101.6 mm ± 1 mm. The specimen is placed in the environmental chamber and
allowed to equilibrate to the specified testing temperature ±1°C. A contact load (P
min) equal to
5% of the dynamic load is applied to the specimen. Sinusoidal loading (P
dynamic
) is applied to the
specimen in a cyclic manner. The dynamic load is adjusted to obtain axial strains between 50 and
150 microstrain.
The recommended test series for the development of master curves for use in pavement
response and performance analysis consists of testing at –10° C, 4.4° C, 21.1° C, 37.8° C, and
54.4° C at loading frequencies of 0.1, 0.5, 1.0, 5, 10, and 25 Hz at each temperature. Testing at a
given temperature begins with the highest frequency of loading and proceeds to the lowest. At
the beginning of testing, the specimen is preconditioned with 200 cycles at 25 Hz. A typical rest
time period between each frequency run is 2 min. This rest period shall not exceed 30 min for
any two-frequency runs.
The suggested procedure includes conditioning requirements modified from those of the
NCHRP Project 9-34 study. Since it is difficult to perform dynamic modulus testing at every
single temperature, one test temperature is selected for the tests conducted at all frequencies.
Flow Number In this test, a cylindrical sample of asphalt concrete mixture is subjected to a
haversine axial load. The load is applied for a duration of 0.1 s with a rest period of 0.9 s. The
rest period has a load equivalent to the seating load. The test can be performed without
confinement, or else a confining pressure is applied to better simulate in situ stress conditions.
Cumulative permanent axial and radial strains are recorded throughout the test. In addition, the
number of repetitions at which shear deformation, under constant volume, starts is defined as the
flow number.
102 Moisture Sensitivity of Asphalt Pavements: A National Seminar
(a) (b)
FIGURE 9 Specimen setup for (a) conditioning and (b) testing.
(a) (b)
FIGURE 10 (a) Testing chamber and (b) environmental
conditioning subsystem for ECS/SPT setup.
Solaimanian, Harvey, Tahmoressi, and Tandon 103
The specimen preparation, size requirements, and placement in the machine are similar to
those of the dynamic modulus test. The only difference is that radial LVDTs are also attached to
the specimen.
The recommended test protocol for the SPT for use in the Superpave volumetric mix
design consists of testing the asphalt mix at one effective pavement temperature T
eff
and one
design stress level selected by the design engineer. The effective pavement temperature T
eff
covers approximately the temperature range of 25° C to 60° C. The design stress levels cover the
range from 69 to 207 kPa for the unconfined tests and from 483 to 966 kPa for the confined tests.
Typical confinement levels range between 35 and 207 kPa. For the NCHRP Project 9-34
research, the test temperature and required stress level are selected within the range specified by
the test procedure.
Flow Time In this test, a cylindrical sample of asphalt concrete mixture is subjected to a static
axial load. The test can be performed without confinement, or a confining pressure may be
applied to better simulate in situ stress conditions. The flow time is defined as the postulated
time when shear deformation, under constant volume, starts. The applied stress and the resulting
permanent or axial strain response of the specimen are measured and used to calculate the flow
time.
Tests Methods to Evaluate Asphalt
Aggregate Adhesion for Surface Treatments and Chip
Seals
Several tests are used particularly to evaluate the adhesion between aggregates and binder in a
chip seal or surface treatment application. The immersion tray, plate, and sand mix tests are
examples.
Immersion Tray Test
In the immersion tray test, a film of binder is placed in a shallow tray and covered with water.
Afterwards, aggregate chips are pressed into the surface of the binder. The chips are removed
after a specified time, and the coverage of the face in contact with binder is estimated visually.
The test provides a general and rough estimate of adhesion strength between asphalt and
aggregate. The rate and magnitude of pressing and pulling force can affect the results.
Plate Methods
In the plate method test, a film of binder is placed on a metal plate. Wet or dry aggregate chips
are pressed or rolled into the surface. The plate may be immersed in water. The adhesion of the
chips is determined by blows to the back of the plate. Chips that fall off are weighed or counted,
or the chips are removed by pliers and the coating determined. The use of wet chips gives a
measure of active adhesion.
Sand Mix Method
Wet sand is mixed or shaken with a solution of binder in solvent. The color and cohesion of the
sand are determined. A black agglomerated sand is a positive result.
104 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Extent of Use of Various Moisture Sensitivity Tests by State Departments of
Transportation
Various versions of AASHTO T283 and ASTM D4867 tests are the most commonly used
procedures within various agencies. A survey by Hicks (1991) showed that almost half of the 44
agencies surveyed were using these procedures before developments made by SHRP (Table 3).
The rating in the table is based on a 0 to 9 scaling, with 9 referring to 100% effectiveness of the
method. A recent survey of 55 agencies (including 50 states) compiled by Aschenbrener
indicates that more agencies have moved toward using these two procedures or their modified
versions after SHRP. Table 4 shows that more than 80% of the agencies that use a moisture
sensitivity test procedure favor AASHTO T283 and ASTM D4867 or a similar procedure. Seven
agencies have reported that they do not use any moisture sensitivity test for design.
In 1988, Kiggundu and Roberts quantified the effectiveness of several tests, on the basis
of test data from various researches, as shown in Table 5.
The success/failure ratings, as established by Kiggundu and Roberts and presented in
Table 5, are based on comparing the laboratory predictions with the field performance ratings. A
higher percent success implies a larger number of “correct” predictions.
TABLE 3 Agencies Using Different Moisture Sensitivity Tests Before SHRP (Hicks 1991)
Average Rating
Test Method
No. of
Agencies
Using
Number
Description of
Effectiveness
Boiling water (ASTM D3625) 9 5 Slight to moderate
Static immersion (AASHTO T182) 3 4 Slight
Lottman (NCHRP 246) 3 7.5 High
Tunnicliff and Root (ASTM D4867) 9 5 Slight to moderate
Modified Lottman (AASHTO T283) 9 7.5 High
Immersion–compression (AASHTO T165) 11 5 Slight to moderate
TABLE 4 Agencies Using Different Moisture Sensitivity
Tests After SHRP
Test Method
No. of
Agencies
Using
Boiling water (ASTM D3625) 0
Static immersion (AASHTO T182) 0
Lottman (NCHRP 246) 3
Tunnicliff and Root (ASTM D4867) 6
Modified Lottman (AASHTO T283) 30
Immersion–compression (AASHTO T165) 5
Wheel tracking 2
SOURCE: R. G. Hicks, L. Santucci, and T. Aschenbrener, “Introduction
and Seminar Objectives” (Topic 1 of this seminar).
Solaimanian, Harvey, Tahmoressi, and Tandon 105
TABLE 5 Success Rates of Test Methods (Kiggundu and Roberts 1988)
Test Method Minimum Test Criteria % Success
Modified Lottman (AASHTO T283) TSR = 70%
TSR = 80%
67
76
Tunnicliff–Root (ASTM D4867) TSR = 70%
TSR = 80%
TSR = 70%–80%
60
67
67
10-minute boil test Retained coating 85%–90% 58
Immersion–compression (AASHTO T165) Retained strength 75% 47
N
OTE
: TSR = tensile strength ratio.
SUMMARY
Moisture damage has been a topic of great interest to asphalt pavement technologists and state
highway agencies for many years. Over the past 70 years, the industry has witnessed
development of a considerable number of tests by many researchers and agencies.
The tests developed fall into general categories: those that are conducted on loose
asphalt–aggregate mixtures and those that are conducted on compacted mixes. Most of the tests
of the first group provide an estimate of the asphalt–aggregate compatibility and stripping
potential. Most of the tests in the second group attempt to take the mix properties, water action,
and traffic into account in different ways. Some of the tests of the second group provide moisture
sensitivity of the mix on the basis of a mix parameter such as strength or modulus before and
after conditioning. Others provide some measure of damage such as permanent deformation to
the mix while being conditioned under combined load and water actions.
Some tests have been calibrated and implemented on a local basis (a region within a
state). No test has been successfully calibrated and implemented across a wide spectrum of
conditions. Reasons for the lack of widespread calibration with field performance include the
limitations of the tests in including all of the effects causing moisture damage, lack of accessible
field performance data, and difficulties with the tests such as variability and difficulty of
operation.
Many variables in the field make field correlation difficult, but development of such a
correlation remains absolutely necessary. This has been a major shortcoming in the development
of effective laboratory tests that can provide quantitative results used in specifications and design
across a wide range of conditions.
Mechanisms of moisture susceptibility/stripping may be different because of the different
variables, but tests and their calibration must take into account materials, construction, traffic,
and climate. The result will be that a given mix will have different risks depending on where and
how it will be used, and these factors must be accounted for in test development, test evaluation
and calibration, and test implementation.
Databases that include the required variables and sufficient numbers of projects do not
exist at this time and are very difficult to develop. However, databases of this type are necessary
for effective calibration of laboratory tests for moisture susceptibility and stripping.
RESOURCES
Alam, M. M. 1997. A Test Method for Identifying Moisture Susceptible Asphalt Concrete Mixes.
M.S. thesis. Department of Civil Engineering, University of Texas at El Paso.
106 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Al-Swailmi, S., and R. L. Terrel. 1992. Evaluation of Water Damage of Asphalt Concrete
Mixtures Using the Environmental Conditioning System (ECS). Journal of the
Association of Asphalt Paving Technologists, Vol. 61.
Al-Swailmi, S., and R. L. Terrel. 1994. Water Sensitivity of AsphaltAggregate Mixtures: Test
Selection. SHRP-A-403. Strategic Highway Research Program, National Research
Council, Washington, D.C.
Al-Swailmi, S., T. V. Scholz, and R. L. Terrel. 1992. Development and Evaluation of Test
System to Induce and Monitor Moisture Damage to Asphalt Concrete Mixtures. In
Transportation Research Record 1353, TRB, National Research Council, Washington,
D.C., pp. 39–45.
Andersland, O. B., and W. L. Goetz. 1956. Sonic Test for Evaluation of Stripping Resistance in
Compacted Bituminous Mixtures. Proc., Association of Asphalt Paving Technologists,
Vol. 25.
Anderson, D. A., and M. E. Shamon. 1984. Fourth Cycle of Pavement Research at the
Pennsylvania Transportation Research Facility, Volume 5: Open-Graded Permeable
Subbases at the Pavement Durability Research Facility. Report FHWA/PA 84-027.
Pennsylvania Transportation Institute, Pennsylvania State University, Dec.
Aschenbrener, T. 1995. Evaluation of Hamburg Wheel-Tracking Device to Predict Moisture
Damage in Hot Mix Asphalt. In Transportation Research Record 1492, TRB, National
Research Council, Washington D.C., pp. 193–201.
Aschenbrener, T., and G. Currier. 1993. Influence of Testing Variables on the Results from the
Hamburg Wheel-Tracking Device. CDOT-DTD-R-93-22. Colorado Department of
Transportation, Denver.
Aschenbrener, T., R. Terrel, and R. Zamora. 1994. Comparison of the Hamburg Wheel Tracking
Device and the Environmental Conditioning System to Pavements of Known Stripping
Performance. Final Report. Colorado Department of Transportation, Denver.
Aschenbrener, T., R. B. McGennis, and R. L. Terrel. 1995. Comparison of Several Moisture
Susceptibility Tests to Pavements of Known Field Performane. Journal of the Association
of Asphalt Paving Technologists, Vol. 64, pp. 163–208.
Bejarano, M. O., and J. T. Harvey. 2002. Accelerated Pavement Testing of Drained and
Undrained Pavements Under Wet Base Conditions. In Transportation Research Record:
Journal of the Transportation Research Board, No. 1816, TRB, National Research
Council, Washington, D.C., pp. 137–147.
Busching, H. W., J. L. Burati, Jr., and S. N. Amirkhanian. 1986. An Investigation of Stripping in
Asphalt Concrete in South Carolina. Department of Civil Engineering, Clemson
University, Clemson, S.C., July.
Cheng, D., D. N. Little, R. L. Lytton, and J. C. Holtse. 2001. Surface Free Energy Measurement
of Aggregates and Its Application on Adhesion and Moisture Damage of Asphalt–
Aggregate System. Proc., 9th International Center for Aggregate Research Symposium,
Austin, Tex.
Cheng, D., D. N. Little, R. L. Lytton, and J. C. Holtse. 2002. Use of Surface Free Energy
Properties of Asphalt–Aggregate System to Predict Damage Potential. Presented at
Annual Meeting of the Association of Asphalt Paving Technologists, March.
Curtis, C. W., K. Ensley, and J. Epps. 1993. Fundamental Properties of AsphaltAggregate
Interactions Including Adhesion and Absorption. SHRP-A-341. Strategic Highway
Research Program, National Research Council, Washington, D.C.
Solaimanian, Harvey, Tahmoressi, and Tandon 107
Elphingstone, G. M. 1997. Adhesion and Cohesion in AsphaltAggregate Systems. Ph.D.
dissertation. Texas A&M University.
Ensley, E. K., J. C. Petersen, and R. E. Robertson. 1984. Asphalt–Aggregate Bonding Energy
Measurements by Microcalorimetric Methods. Thermochimica Acta, Vol. 77, p. 95.
Epps, J. A., P. E. Sebaaly, J. Penaranda, M. R. Maher, M. B. McCann, and A. J. Hand. 2000.
NCHRP Report 444: Compatibility of a Test for Moisture-Induced Damage with
Superpave Volumetric Mix Design. TRB, National Research Council, Washington, D.C.
Ford, M. C., Jr., P. G. Manke, and C. E. O’Bannon. 1974. Quantitative Evaluation of Stripping
by the Surface Reaction Test. In Transportation Research Record 515, TRB, National
Research Council, Washington, D.C., pp. 40–54.
Gharaybeh, F. A. 1987. Evaluation of Tests to Assess Stripping Potential for Asphalt Concrete
Mixtures. Dissertation. Department of Civil Engineering, Auburn University, Ala., Aug.
Goode, F. F. 1959. Use of Immersion Compression Test in Evaluating and Designing
Bituminous Paving Mixtures. In ASTM STP 252, pp. 113–126.
Hallberg, S. 1950. The Adhesion of Bituminous Binders and Aggregates in the Presence of
Water. Statens Vaginstitut, Stockholm, Sweden.
Harvey, J., C. Monismith, and Q. Lu. 2002. Moisture Sensitivity (MS) Identification Flowchart.
Draft memorandum. Prepared for Caltrans/Industry subcommittee, March.
Hicks, R. G. 1991. NCHRP Synthesis of Highway Practice 175: Moisture Damage in Asphalt
Concrete. TRB, National Research Council, Washington, D.C.
Hubbard, P. 1938. Adhesion of Asphalt to Aggregate in Presence of Water. Highway Research
Board Proceedings, Vol. 18, Part 1, pp. 238–249.
Hveem, F. 1943. Quality Tests for Asphalt: A Progress Report. Proc., Association of Asphalt
Paving Technologists, Vol. 15, pp. 111–152.
International Slurry Seal Association. 1989. A Test Method for Determination of Methylene Blue
Absorption Value (MBV) of Mineral Aggregate Fillers and Fines. ISSA Bulletin 145.
Isacsson, W., and T. Jorgensen. 1987. Laboratory Methods for Determination of the Water
Susceptibility of Bituminous Pavements. VIT report, Swedish Road and Traffic Research
Institute, No. 324A.
Jimenez, R. A. 1974. Testing for Debonding of Asphalt from Aggregates. In Transportation
Research Record 515, TRB, National Research Council, Washington, D.C., pp. 1–17.
Johnson, D. L. 1969. Debonding of Water-Saturated Asphaltic Concrete Caused by Thermally
Induced Pore Pressure. MSCE thesis. University of Idaho, Moscow.
Kandhal, P. S., C. Y. Lynn, and F. Parker. 1998. Tests for Plastic Fines in Aggregates Related to
Stripping in Asphalt Paving Mixtures. Journal of the Association of Asphalt Paving
Technologists, Vol. 67.
Kennedy, T. W., F. L. Roberts, and K. W. Lee. 1982. Evaluation of Moisture Susceptibility of
Asphalt Mixtures Using the Texas Freeze–Thaw Pedestal Test. Proc., Association of
Asphalt Paving Technologists, Vol. 51, pp. 327–341.
Kennedy, T. W., F. L. Roberts, K. W. Lee, and J. N. Anagnos. 1982. Texas FreezeThaw
Pedestal Test for Evaluating Moisture Susceptibility for Asphalt Mixtures. Research
Report 253-3. Center for Transportation Research, University of Texas at Austin, Feb.
Kennedy, T. W., F. L. Roberts, and J. N. Anagnos. 1984. Texas Boiling Test for Evaluating
Moisture Susceptibility of Asphalt Mixtures. Research Report 253-5. Center for
Transportation Research, University of Texas at Austin, Jan.
108 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Kennedy, T. W., F. L. Roberts, and K. W. Lee. 1984. Evaluating Moisture Susceptibility of
Asphalt Mixtures Using the Texas Boiling Test. In Transportation Research Record 968,
TRB, National Research Council, Washington, D.C., pp. 45–54.
Kennedy, T. W., and J. N. Anagnos. 1984. Modified Test Procedure for Texas FreezeThaw
Pedestal Test. CTR 3-O-79-253-7. University of Texas at Austin, Nov.
Kennedy, T. W., and J. N. Anagnos. 1984. WetDry Indirect Tensile Test for Evaluating
Moisture Susceptibility of Asphalt Mixtures. Research Report 253-8. Center for
Transportation Research, University of Texas at Austin, Nov.
Kiggundu, B. M., and F. L. Roberts. 1988. Stripping in HMA Mixtures: State-of-the-Art and
Critical Review of Test Methods. NCAT Report 88-2. National Center for Asphalt
Technology.
Kiggundu, B. M., and F. L. Roberts. 1988. The Success/Failure of Methods Used to Predict the
Stripping Potential in the Performance of Bituminous Pavement Mixtures. Submitted to
TRB.
Krchma, L. C., and R. J. Loomis. 1943. Bituminous–Aggregate Water Resistance Studies. Proc.,
Association of Asphalt Paving Technologists, Vol. 15, pp. 153–187.
Krchma, L. C., and H. G. Nevitt. 1942. Absorption of Liquid Bituminous Cement by Aggregates.
Proc., Association of Asphalt Paving Technologists, Vol. 13.
Lottman, R. P. 1971. The Moisture Mechanism That Causes Asphalt Stripping in Asphaltic
Pavement Mixtures. Final Report R-47. Engineering Experimental Station, Department of
Civil Engineering, University of Idaho, Moscow, Feb.
Lottman, R. P. 1978. NCHRP Report 192: Predicting Moisture-Induced Damage to Asphaltic
Concrete. TRB, National Research Council, Washington, D.C.
Lottman, R. P. 1982. NCHRP Report 246: Predicting Moisture-Induced Damage to Asphaltic
Concrete: Field Evaluation. TRB, National Research Council, Washington, D.C.
Lu, Q. 2003. Investigation of Conditions for Moisture Damage in Asphalt Concrete and
Appropriate Laboratory Test Methods. Proposal for doctoral thesis. Department of Civil
and Environmental Engineering, University of California, Berkeley.
Majidzadeh, K., and F. N. Brovold. 1966. Effect of Water on BitumenAggregate Mixtures.
Report CE-1. University of Florida.
Maupin, G. W., Jr. 1980. Detection of Antistripping Additives with Quick Bottle Test. Final
Report. Virginia Highway and Transportation Research Council, Charlottesville, Oct.
McLeod, N. 1937. Applications of Surface Chemistry and Physics to Bituminous Mixtures.
Proc., Association of Asphalt Paving Technologists, pp. 1–62.
Nicholson, V. 1932. Proc., Association of Asphalt Paving Technologists, pp. 30–31.
Philips, P. S., and C. R. Marek. 1986. HMA Moisture Susceptibility Problems: The Need to Test
and Specify via a Common Procedure. Symposium presentation, ASTM, New Orleans,
La., Dec.
Plancher, H., G. Miyake, R. L. Venable, and J. C. Petersen. 1980. A Simple Laboratory Test to
Indicate Moisture Susceptibility of Asphalt–Aggregate Mixtures to Moisture Damage
During Repeated Freeze–Thaw Cycling. Canadian Technical Asphalt Association
Proceedings, Vol. 25, pp. 247–262.
Powers. 1938. Proc., Montana National Bituminous Conference, pp. 321–338.
Rice, J. M. 1958. Relationship of Aggregate Characteristics to the Effect of Water on Bituminous
Paving Mixtures. Symposium on Effect of Water on Bituminous Paving Mixtures. In
ASTM STP 240, pp. 17–34.
Solaimanian, Harvey, Tahmoressi, and Tandon 109
Riedel, W., and H. Weber. 1934. Asphalt und Teer.
Road Research Laboratory. 1986. TMH1: Standard Methods of Testing Road Construction
Materials. Method B11: The Determination of the Adhesion of Bituminous Binder to
Stone Aggregate by Means of the Chemical Immersion Test (Riedel Weber). England.
Romero, F. L., and K. D. Stuart. 1998. Evaluating Accelerated Rut Testers. Public Roads, Vol.
62, No. 1, July–Aug., pp. 50–54.
Saville, V., and E. Axon. 1937. Adhesion of Asphaltic Binders to Mineral Aggregates.
Association of Asphalt Paving Technologists, Proceedings of the Technical Sessions,
Dec., pp. 87–101.
Schmidt, R. J., and P. E. Graf. 1972. The Effect of Water on the Resilient Modulus of Asphalt
Treated Mixes. Proc., Association of Asphalt Paving Technologists, Vol. 41, pp. 118–
162.
Scholz, T. V., R. L. Terrel, A. Al-Joaib, and J. Bea. 1994. Water Sensitivity: Binder Validation.
SHRP-A-402. Strategic Highway Research Program, National Research Council,
Washington, D.C.
Shatnawi, S., M. Nagarajaiah, and J. Harvey. 1995. Moisture Sensitivity Evaluation of Binder–
Aggregate Mixtures. In Transportation Research Record 1492, TRB, National Research
Council, Washington, D.C., pp. 71–84.
Solaimanian, M., and T. W. Kennedy. 2000a. Precision of the Moisture Susceptibility Test
Method Tex 531-C. Research Report 4909-1F. Center for Transportation Research,
University of Texas at Austin.
Solaimanian, M., and T. W. Kennedy. 2000b. Relationship Between Aggregate Properties and
Hamburg Wheel Tracking Results. Research Report 4977-1F. Center for Transportation
Research, University of Texas at Austin.
Solaimanian, M., T. W. Kennedy, and W. E. Elmore. 1993. Long-Term Evaluation of Stripping
and Moisture Damage in Asphalt Pavements Treated with Lime and Antistripping Agents.
Texas Department of Transportation Report CTR 0-1286-1F. Center for Transportation
Research, University of Texas at Austin.
Stuart, K. D. 1986. Evaluation of Procedures Used to Predict Moisture Damage in Asphalt
Mixtures. FHWA/RD-86/091. Draft report, March.
Stuart, K. D., and R. P. Izzo. 1995. Correlation of Superpave G*/sin δ with Rutting
Susceptibility from Laboratory Mixture Tests. In Transportation Research Record 1492,
TRB, National Research Council, Washington, D.C., pp. 176–183.
Stuart, K. D., and W. S. Mogawer. 1995. Effect of Coarse Aggregate Content on Stone Matrix
Asphalt Durability and Low-Temperature Cracking. In Transportation Research Record
1492, TRB, National Research Council, Washington, D.C., pp. 26–35.
Stuart, K. D., and W. S. Mogawer. 1997. Validation of Asphalt Binder and Mixture Tests That
Predict Rutting Susceptibility Using the Federal Highway Administration’s Accelerated
Loading Facility. Presented at 1997 Annual Meeting of the Association of Asphalt
Paving Technologists, Salt Lake City, Utah.
Tandon, V., N. Vemuri, S. Nazarian, and M. Tahmoressi. 1997. A Comprehensive Evaluation of
Environmental Conditioning System. Journal of the Association of Asphalt Paving
Technologists, Vol. 66.
Tandon, V., and S. Nazarian. 2001. Modified Environmental Conditioning System: Validation
and Optimization. Research Report TX-01/1826-1F. Center for Highway Materials
Research, University of Texas at El Paso.
110 Moisture Sensitivity of Asphalt Pavements: A National Seminar
Thelen, E. 1958. Surface Energy and Adhesion Properties in Asphalt–Aggregate Systems.
Bulletin 192, HRB, National Research Council, pp. 63–74.
Tunnicliff, D. G., and R. Root. 1982. Antistripping Additives in Asphalt Concrete: State-of-the-
Art. Proc., Association of Asphalt Paving Technologists, Vol. 51.
Tunnicliff, D. G., and R. E. Root. 1984. NCHRP Report 274: Use of Antistripping Additives in
Asphaltic Concrete Mixtures. Laboratory phase. TRB, National Research Council,
Washington, D.C.
White, G. C., J. P. Mahoney, G. M. Turkiyyah, K. A. Willoughby, and E. R. Brown. 2002.
Online Tools for Hot-Mix Asphalt Monitoring. In Transportation Research Record:
Journal of the Transportation Research Board, No. 1813, TRB, National Research
Council, Washington, D.C., pp. 124–132.
Winterkorn, H. 1937. Proc., Montana National Bituminous Conference, pp. 190–214.
Winterkorn, H. 1938. Proc., Montana National Bituminous Conference, pp. 136–143.
Winterkorn, H. 1939. Proc., Montana National Bituminous Conference, pp. 118–134.
Winterkorn, H., G. Eckert, and E. Shipley. 1937. Testing the Adhesion Between Bitumen and
Mineral Surfaces with Alkaline Solutions. Proc., Association of Asphalt Paving
Technologists, pp. 63–85.
Youtcheff, J., and V. Aurilio. 1997. Pneumatic Pull-Off Test. 42nd Canadian Technical Asphalt
Association Proceedings.
111
TOPIC 3
Questions and Answers
MANSOUR SOLAIMANIAN
Pennsylvania State University, Speaker
Q1—John D’Angelo, Federal Highway Administration
I will agree with you. I think one of the big things we have to do in any of this testing is try and
simulate what’s happening in the field. But as I went through all the testing you showed here,
you always talked about making specimens in the 7% range, plus or minus. I am really a
believer that we’re not even close to what’s going on in the field. I think a lot of what we see in
the field is actually much higher air voids, and that’s a big problem in that it’s not being
recognized yet. How can we get a lab test to correlate to the field when the lab voids aren’t even
close to what’s going on in the field? Have you looked at all at trying to address some of these
issues, particularly about what’s really happening in the field and what level of compaction we
really have out there? I’ll let you go from there.
A—Mansour Solaimanian
Thank you, John. I do agree with you. The construction air void has a major effect, and that
needs to be looked at very closely. It’s not just a matter of stripping when you talk about the air
void effect. It’s also considering the effect of air voids on rutting. You do your mix design, and
then you make your specimens at 7% air voids, for example, for performance testing. Then you
make your prediction of the performance of the mix and you wonder how this correlates with the
field air voids. So that is a very general question. It’s not just for stripping, it’s for rutting and
fatigue and other properties that you try to simulate or predict in the laboratory. So as part of this
project, one of the things that we plan to do is to consider the air void effects in these tests and
get them to the typical acceptable levels in the field. I think most states don’t accept a mix if the
density is under 90%. Maybe we should take the air voids to the lowest acceptable level even
though a penalty might be applied. We should then see how the results compare in terms of your
failure and success with a 7% or any other air void level we are currently working on. Right now,
we have only been looking at a typical level of air voids that has been used in T283 and other test
procedures.
Q2—Dale Rand, Texas Department of Transportation
On the slide that showed the percentage of success, can you elaborate on the criteria used on the
percentage of success? Was that an opinion or was that based on something else? It kind of
implies that the test correlates with something.
A—Mansour Solaimanian
You notice that at the bottom of the slide, I had Kiggundu and Roberts. I took the data directly
from their interpretation of failure and success, and I believe they looked at the mixes that had
stripped and the mixes that did not strip or were considered good. I do not know what exactly
their criteria have been on deciding which one had been a stripping mix in the field and which
one not. They looked at the laboratory results and made a comparison against the field data.
112 Moisture Sensitivity of Asphalt Pavements: A National Seminar
They decided which ones correlated well with the stripping ones and which ones did not. This
way, they came up with percentages to indicate rate of success in prediction. For example, if a
material is stripped in the field, and the lab criterion is 70% on TSR while we get 60%, then we
consider this a successful prediction. On the other hand, if a mix had stripped and we had a TSR
of 90%, then the prediction was not successful.
Q3—Gayle King, Koch Pavement Solutions
Mansour, great presentation. I find it interesting that you emphasize the methylene blue test but
don’t talk about sand equivalency. My own prejudice lies in that same direction. A French
sabbatical gave me a strong appreciation for the surface activity of fines, particularly as related to
moisture damage in mixes. Of course methylene blue is now part of ISSA microsurfacing
specifications, because fines also have a strong impact on emulsion break. Studies by Tim
Aschenbrener and Ken Kandhal showed similar correlations between methylene blue and
Hamburg. Although correlations weren’t perfect, Hamburg consistently failed when methylene
blue was high. The entire experimental scatter fell in the region where methylene blue was low,
because mixes will strip in the Hamburg for reasons other than surface-active fines. The message
was clear, mixes consistently stripped when methylene blue was high. Do we get that same
information from sand equivalency? Or should we replace sand equivalency with methylene
blue?
A—Mansour Solaimanian
I am not sure I can answer your question but I will try. I do agree with you that methylene blue is
a very good test. In terms of how good the r
2
was in every case, I was just reporting what I
noticed from Ken’s work. I suppose the r
2
values were around 70%. But again, this is just based
on his data. On replacing SE with MB, I am not sure you will be capturing the same thing
because when you do the methylene blue, you are doing it on –200 material in the mix, and when
you do your sand equivalency, you are basically doing it on material passing the No. 4 sieve.
You do have an amount of fines in your mix that you need to watch out, regardless of your
testing. You might have 4% of –200 material, but you should watch out that this material might
contain a lot of bad clay. You still need to look at your sand equivalency to make sure your
material passing the No. 4 sieve is OK. I may not have answered your question very clearly.
Q4Jack Van Kirk, Basic Resources, Inc.
I have two questions. One is that after SHRP, you said a lot of the states switched over, and a
total of 30 are now using T283. The first question is, Why did a lot of those states change over?
What convinced them? The second question is, How much variability is in the parameters or the
criteria they are using to run the test? Everything from voids in the specimens to saturation levels
to compaction method can introduce differences between states and variability within a state.
A—Mansour Solaimanian
Why so many states picked it up, you want to answer that, Gary? I don’t know. I guess because it
became a part of the Superpave Design System. With regard to your second question on
variability, there is variability between technicians in a given state, and between different states
depending on where you are in terms of your air voids and your testing procedures. It is a big
deal.
Solaimanian, Harvey, Tahmoressi, and Tandon 113
Q5Dick Root, Root Pavement Technology, Inc.
Maybe a couple of comments on the procedure itself and maybe why it was adopted indirectly. I
was a little bit confused by a couple of your comments, so maybe you can help clear me up on
this. First of all, T283 and ASTM D4867 are the same test. One was performed or put together
by a research team, and the other was put together by a committee, so they got a little bit deviant
in the committee aspect of it. The control of air voids and saturation levels, you made an
indication, or at least I perceive, that would affect the test results or maybe cause errors in it.
There were several studies done during the original research and follow-up studies by Irv Dukatz
at Vulcan Materials that showed that with a range of air voids at 6–8 and with the saturation
levels of 55–80, you essentially get the same results for a ratio of strengths, not individual
strength. Obviously, the PSI would be different at 6% voids than 8%, but when you start looking
at ratios, that narrowed the data down to very, very close. I think the reason for the adoption of it
is simple. It can be run in the field and it was reasonably an advancement over what we were
running previous to that, boiling water tests and emergent compression tests.
A—Mansour Solaimanian
Yes, ASTM D4876 and AASHTO T283 I think are essentially the same, but if you look at the
procedures, there is a 16-hour curing in AASHTO T283 that does not exist in ASTM D4867.
Other than that, you are right. Curing is very different between the two procedures. I would be
interested in seeing that data that you mentioned in terms of essentially getting the same ratio and
see how big the database or what kind of data has been used in there.
Q6—Carl Monismith, University of California, Berkeley
I think that your answer why T283 was adopted is correct because many states, immediately after
the completion of SHRP, adopted the Superpave method of mix design, and T283 is a part of the
methodology. The other thing I wanted to mention is this matter of the sand equivalent and
methylene blue tests. The sand equivalent test was developed circa 1950; information regarding
the test was published by the Highway (now Transportation) Research Board by F. N. Hveem in
1952. The primary purpose of the test is to eliminate the potential for detrimental clay coatings
on aggregate particles, coatings that could result from improper processing of aggregates
obtained from alluvial deposits. I would argue that it would be extremely imprudent to replace
the sand equivalent test with the methylene blue test; the sand equivalent test is a very important
test for the control of fines. If pavement technologists want to look at the nature of these fines,
methylene blue is a useful additional test. As noted above, to replace one with the other would be
unwise.
AMansour Solaimanian
I agree, Carl.